1 documents found
Information × Registration Number 0209U001457, 0106U012467 , R & D reports Title Development of nanocrystalline tape wound magnetic cores with high stability for high precision measurement current transformers for electrical net in Ukraine. popup.stage_title Head Maslov V.V., Registration Date 04-02-2009 Organization Institute of Metal Physic G.V.Kurdyumov NAS of the Ukraine popup.description2 Production technique developed and pilot-commercial and commercial batches of magnetic cores for high-class current measuring transformers for needs of domestic instrument-making enterprises are manufactured; group and technical specification on tape wound magnetic core from ММ-11Н alloy for Current Measuring Transformers 50/5А - 3000/5 А is developed. Product Description popup.authors popup.nrat_date 2020-04-02 Close
R & D report
Head: Maslov V.V.. Development of nanocrystalline tape wound magnetic cores with high stability for high precision measurement current transformers for electrical net in Ukraine.. (popup.stage: ). Institute of Metal Physic G.V.Kurdyumov NAS of the Ukraine. № 0209U001457
1 documents found

Updated: 2026-03-28