Information × Registration Number 0221U100399, 0116U004233 , R & D reports Title Creating of high sensitive X-ray TV portable digital system on the base of digital mini flat panel detectors for local testing of energy equipment and aerispace popup.stage_title Head Troitskiy Volodymyr O., Доктор технічних наук Registration Date 05-01-2021 Organization E.O.Paton Elektric Welding Institute National Academy of scinces of Ukraine popup.description2  ) For the first time in the world practice, a portable high-sensitivity X-ray digital system has been created instead of film radiography and expensive full-format flat-panel detectors, which uses inexpensive small-format high-sensitivity digital X-ray sensors widely used in dentistry. The principle of scanning objects that is used is the following: the separate adjacent fragments of digital X-ray images are stitched into a single full-size digital image. Compared to full-format sensors, the price of such systems is an order of magnitude lower, and the resolution is 5 times higher. The time to obtain a radiation image of 300 x 40 mm is up to 3 minutes, which is 10 times faster than when using the film, because it does not require chemical treatment. Product Description popup.authors Pockets Mykhailo M Mikhaĭlov Sergey R popup.nrat_date 2021-01-05 Close
R & D report
Head: Troitskiy Volodymyr O.. Creating of high sensitive X-ray TV portable digital system on the base of digital mini flat panel detectors for local testing of energy equipment and aerispace. (popup.stage: ). E.O.Paton Elektric Welding Institute National Academy of scinces of Ukraine. № 0221U100399