1 documents found
Information × Registration Number 0222U004850, 0122U201289 , R & D reports Title Services for measuring the parameters of the high-voltage part of NDETU EM-01-2019 popup.stage_title Head Haran Yaroslav O., Кандидат технічних наук Registration Date 14-11-2022 Organization National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute" popup.description2  The parameters of the high-voltage modules of the NDETU EM-01-2019 were analyzed for changes (instability) in the ratios of reference capacitance values, differences in tangents of the dielectric loss angles of high-voltage insulation, and parameters of electric power consumption. It was determined that the parameters of the ratio of the reference capacities and the difference of the tangents of the dielectric loss angles of the high-voltage insulation are within the normalized limits. Regulatory work with high-voltage insulation led to a decrease in electric power consumption by the DZS-520-1 high-voltage module. Product Description popup.authors Trotsenko Yevgeniy O popup.nrat_date 2022-11-14 Close
R & D report
Head: Haran Yaroslav O.. Services for measuring the parameters of the high-voltage part of NDETU EM-01-2019. (popup.stage: ). National Technical University of Ukraine "Igor Sikorsky Kyiv Polytechnic Institute". № 0222U004850