1 documents found
Information × Registration Number 0224U001910, 0122U001266 , R & D reports Title Models and means to prevent the deterioration of the quality of power supply of industrial consumers (code: Monitor-4) popup.stage_title Head Kyrylenko Oleksandr V., Доктор технічних наук Registration Date 02-02-2024 Organization Institute of Electrodynamics of the National Academy of Sciences of Ukraine popup.description2  Schematic and technical solutions are proposed for correcting start-up modes that arise in the electrical network as a result of direct sequential start-up from the network of several asynchronous machines, in particular, standby cooling pumps of thermal and nuclear power plants. A model of the network that feeds the powerful controlled rectifier in the means of adjustment of starting modes is built. To solve the practical problem of determining the optimal location and placement scheme of automatic sectionalizing switchgear in distribution electrical networks, an adapted model for evaluating the optimal number and installation locations of sectional switching devices in distribution electrical networks is proposed. A study of voltage deviation and its fluctuations in distribution networks with a voltage of 110-220 kV, a study of voltage non-sinusoidality and asymmetry, dips and temporary voltage overshoots, as well as deviation of the frequency of the main voltage harmonic from nominal values using emergency situations registered by hardware and software means of information- of the "Regina" diagnostic complex. The obtained results were summarized and the quality indicators of electric energy were checked for compliance of their parameters with permissible and marginally permissible quality standards. A method of detection of single-phase earth faults in the distribution network based on the method of detection of seismic events STA/SLA is proposed. A technique for determining the trigger thresholds of the STA/SLA algorithm has been developed, which allows for a reliable determination of a single-phase ground fault. The actuation limits are defined in relative units, which allows the method to be adapted to changes in the network configuration. Product Description popup.authors Ivanochok Nataliya D. Balanyuk Nataliya B. Blinov Ihor V. Borovyk Yuriy M. Varsky Grigory M. Voytov Dmytro V. Guy Olexandr V. Hnatyshyna Olena А. Horbovetsʹ Viktoriya А. Grechko Vyacheslav V. Dovhodʹko Yuriy M. Dyachuk Sergij Ivanovych Diachuk Tetiana M. Zakharov Artem V. Kyrylenko Oleksandr V. Kozenyuk Ihor M. Kostiuk Andrii R. Koshman Vsevolod І. Kuznetsov Volodymyr H. Kuchansky Vladislav V. Lenha Oleh V. Marshevsʹkyy Andriy S. Mykhaylevsʹkyy Oleh S. Nikishyn Dmytro А. Nevechera Ihor V. Pavlovskyi Vsevolod V. Panov Anatolii V. Parus Eugene V. Pilipenko Yuriy V. Prykhodko Anna V. Rak Svitlana Ye. Reznik Svitlana O. Rybina Oksana B Sabarno Ludmila R. Sevastyuk Ihor M. Slyn'ko Volodymyr M. Spodynsʹkyy Oleksandr V. Stelyuk Anton O. Stognii Borys S. Trach Igor V. Tugai Iryna Y. Tuhai Yurii I. Khrapak Oleksandr I. Cherepanova Valentuna M. Chyzhenko Oleksandr I. Chukhnov Oleh H. Shpolyansʹkyy Oleh H. popup.nrat_date 2024-02-02 Close
R & D report
Head: Kyrylenko Oleksandr V.. Models and means to prevent the deterioration of the quality of power supply of industrial consumers (code: Monitor-4). (popup.stage: ). Institute of Electrodynamics of the National Academy of Sciences of Ukraine. № 0224U001910
1 documents found

Updated: 2026-03-27