Information × Registration Number 0301U002565, 0101U001048 , R & D reports Title The analysis of reason of destruction of ammoniac refrigerating machnery and issue of the recjmmendations on increase of his serviceability. popup.stage_title Аналіз причин руйнування аміачного холодильного обладнання та видача рекомендацій по підвищенню його роботоздатності. Head Kachanov V. A., Registration Date 28-09-2001 Organization Ukrainian Research and Design Institute for Chemical Engineering Joint - stock company popup.description2 The work was conducted with the purpose of removal of the reasons of destruction of elements of constructions of the refrigerating equipment. The methodical recommendations for fulfilment of the express train - analysis of steel 09Г2С-12 on state standard 5520 and state standard 19284 are developed. The influence of a level of residual voltages after welding on propensity to corrosion cracking of welded junctions is established become 09Г2С-12 and Ст3сп5. Product Description popup.authors popup.nrat_date 2020-04-02 Close
R & D report
Head: Kachanov V. A.. The analysis of reason of destruction of ammoniac refrigerating machnery and issue of the recjmmendations on increase of his serviceability.. (popup.stage: Аналіз причин руйнування аміачного холодильного обладнання та видача рекомендацій по підвищенню його роботоздатності.). Ukrainian Research and Design Institute for Chemical Engineering Joint - stock company. № 0301U002565