1 documents found
Information × Registration Number 0303U001059, 0101U000186 , R & D reports Title The development of approaches to creation of quality assurance system for dosimetry in diagnostic radiology and radiotherapy.. popup.stage_title Вивчення особливостей формування основних структурних елементів системи забезпечення якості дозиметрії в променевій діагностиці і променевій терапії. Head Pilipenko M.I., Registration Date 20-01-2003 Organization Grigor'ev Institut for Medical Radiology popup.description2 Object of the study: physico-technical parameters of x-ray diagnostic and therapeutic equipment, conditions of x-ray diagnostic studies, statistical data about the number and structure of x-ray diagnostic procedures, individual exposure doses in patients and personnel at the procedures. Purpose of the work: to optimize medical exposure of the population with determining the approaches to creating of the system for provision of the quality of dosimetry in radiodiagnosis and radiotherapy. Methods: ionization and thermofluorescent dosimetry, statistical analysis of the dose load in the personnel. Results: The analysis of the questionnaires with the information about the number of x-ray studies performed in medical institutions of Ukraine was completed. The conditions of formation of the doses in the personnel at x-ray studies were investigated, the groups for obligatory control were determined. Tests for investigation of the physico-technical parameters of x-ray diagnosis and radiotherapy were worked out. The forms of measurement protocols were worked out. Individual doses of patient exposure were determined with thermofluorescent dosimeters and ODS-60 program. The forms of protocols for determining exposure doses in the patients at x-ray diagnostic procedures were worked out. Area of application: medicine, radiodiagnosis, radiotherapy, hospitals. Significance of the work: creation of the suggested system for dosimetry quality assurance in Ukraine will improve the quality of treatment of cancer patients and reduction of the dose load in patients and personnel during x-ray diagnostic procedures. Product Description popup.authors popup.nrat_date 2020-04-02 Close
R & D report
Head: Pilipenko M.I.. The development of approaches to creation of quality assurance system for dosimetry in diagnostic radiology and radiotherapy... (popup.stage: Вивчення особливостей формування основних структурних елементів системи забезпечення якості дозиметрії в променевій діагностиці і променевій терапії.). Grigor'ev Institut for Medical Radiology. № 0303U001059
1 documents found

Updated: 2026-03-20