1 documents found
Information × Registration Number 0305U005293, 0105U004470 , R & D reports Title Development, manufacture and implementation of a specialised crack indicator "IT-2" popup.stage_title Розробка, виготовлення та впровадження специалізованого індикатора тріщин "ИТ-2" Head Bozhko A.E., Registration Date 31-08-2005 Organization A. Podgorny's Institute of Mechanical Engeneering Problems of the National Academy of Science of Ukraine popup.description2 To detect surface cracks in magnetic and non-magnetic metal products, a reliable portable indicator-type instrument has been developed. It is based on the resonance method of eddy-current monitoring. IT-2 is used widely for testing surface layers of different structure. Depending on customer's requirements, and test conditions, the instrument can be designed for different sensitivity characteristics, and with a different set of probes, e.g. a probe with the width of the working zone up to 100 мм for monitoring big surfaces. The instrument can be used for testing parts and assemblies in metro and railway rolling stock; for testing drilling equipment parts, including threads of couplings and drill pipe pins; parts of compressor equipment such as vanes, babbit inserts of bearings, fastening bolts, etc. Product Description popup.authors popup.nrat_date 2020-04-02 Close
R & D report
Head: Bozhko A.E.. Development, manufacture and implementation of a specialised crack indicator "IT-2". (popup.stage: Розробка, виготовлення та впровадження специалізованого індикатора тріщин "ИТ-2"). A. Podgorny's Institute of Mechanical Engeneering Problems of the National Academy of Science of Ukraine. № 0305U005293
1 documents found