Title
Developing, making and applying device for quality monitoring of cylinder joints - stator winding of synchronous generator of a type ГС- 501A
popup.stage_title
Head
Polischuk O.,
Registration Date
28-01-2013
Organization
A.Podgorny Institute of Mechanical Engineering Problems of the National Academy of Science of Ukraine
popup.description2
Developed eddy current device is designed to monitor the quality of solder joints "sleeve - stator winding" type ГС-501A synchronous generators. The principle of operation of the device is based on the method of eddy currents. Parameter control is a voltage measuring winding eddy current transformer converter core asymmetric U-shaped type, which depends on the state-controlled solder. Determining the level of solder joints are controlled on the basis of the experimentally established the connection between the device and the testimony propayanostyu these compounds. The device is made based on a microprocessor, the display of the results is carried out on the digital display with the ability to recruit and retain information (1000 of memory cells). Data transfer to PC via USB port
Product Description
popup.authors
Божко Олександр Євгенович
Поліщук Олег Федорович
Тертишний Іван Сергійович
popup.nrat_date