Registration Number
0218U006493,
0116U006367
, R & D reports
Title
Extending life and increase reliability of radiation monitoring of nuclear energy by developing a wide-range of domestic gas proportional detector of gamma radiation.
popup.stage_title
Head
Kutniy Volodymir Yevdokimovich,
Registration Date
23-05-2018
Organization
National Science Center "Kharkiv Institute of Physics & Technology"
popup.description2
For the study of the electrophysical and radiation characteristics of detectors in the proportional mode of operation, two types of prototypes were made: with planar parallel-placed electrodes and with cylindrical shape with an anode in the form of a thin thread located in the center of a thin-walled tube. Detectors were filled with gas mixture inert gas Xe + 0.25%H2 at different pressures. A spectrometric channel was developed and manufactured. Under the influence of 137Cs isotope gamma-ray irradiation, the detection properties of the detector with the planar-parallel electrodes were investigated. The amplitude distributions of the detector signal in the proportional mode and its counting characteristics were measured. The amplitude of the input signal of a cylindrical detector at the pressure of 100 kPa of the gas mixture Xe + 0.25% H2 was investigated.
Product Description
popup.authors
Антоненко М.І.
Рибка О.В.
Соколов С.О.
Улибкин О.Л.
Шляхов І.М.
popup.nrat_date
2020-04-02