Sanitary-epidemiological assessment of insolation conditions of the surrounding buildings according to the materials "New construction of a multi-apartment residential building with commercial premises of public purpose on the street. Bazarniy, 36 in Lviv"
popup.stage_title
«Санітарно-епідеміологічна оцінка умов інсоляції навколишньої забудови згідно матеріалів «Нове будівництво багатоквартирного житлового будинку з комерційними приміщеннями громадського призначення на вул. Базарній, 36 у м. Львові»»
Head
Semashko Petro V., Доктор медичних наук
Registration Date
07-03-2024
Organization
State Institution "OM Marzeev Institute of Public Health of the National Academy of Medical Sciences of Ukraine"
popup.description1
Sanitary-epidemiological assessment of insolation conditions of the surrounding buildings according to the materials "New construction of a multi-apartment residential building with commercial premises of public purpose on the street. Bazarniy, 36 in Lviv"
popup.description2
Scientific report on the results of scientific sanitary and epidemiological assessment of project materials "Construction of a residential building with built-in non-residential premises located at: Lviv region, Lviv district, Lviv, 36 Bazarna Street" in terms of the impact on insolation of the nearest residential buildings at 36 Bazarna Street. The design materials for the construction of a residential building at 36 Bazarna Street, Lviv, were developed by the customer's request. The analysis of the provided calculations shows that the duration of continuous insolation of the calculating room of a one-room apartment located in the northern part of the western facade of the building is 2 hours. 30 min. and intermittent - 2 hours. 45 minutes, which corresponds to the standard.
The analysis of the provided calculations shows that the projected building will not affect the insolation on the day of the equinox (normative) of one-room apartments located in the central and southern part of the western facade of the existing building (on the first and second floor).
The analysis of the provided calculations shows that the duration of continuous insolation of the calculating room of the mezzanine apartment located in the northern part of the western facade of the building is more than 2 hours. 30 minutes, which corresponds to the standard.
Since the most unfavorable insolation rooms in the specified residential building were used for the calculations, the insolation in all other rooms of the western facade of the building, which may be affected by future construction, will be the same or higher.