Registration Number
0225U000524,
(0124U000383)
, R & D reports
Title
Biomechanical evaluation of the influence of acetabular components configuration on the hip joint endoprosthesis fixation stability
popup.stage_title
Визначення перспективних конструкцій ацетабулярних компонентів ендопротеза кульшового суглоба на основі аналізу сучасних світових тенденцій ендопротезування. Розробка скінченно-елементної моделі для дослідження напружено-деформованого стану елементів здорового кульшового суглоба при експлуатаційних навантаженнях.
Head
Mokrii Tetiana F., Кандидат технічних наук
Registration Date
13-01-2025
Organization
Institute of Technical Mechanics of the National Academy of Sciences of Ukraine and the State Space Agency of Ukraine
popup.description1
Biomechanical evaluation of fixation stability of different designs of hip joint endoprosthesis acetabular components by mathematical simulation of their behaviour in the “cup-hip bone” system to improve the results of hip arthroplasty.
popup.description2
The object of the research is hip joint endoprosthesis. The purpose of the work at the first stage of the research is to determine promising hip joint endoprosthesis acetabular component designs and develop a finite-element model for studying the stress-strain state of elements of healthy hip joint under operational loads. Research methods are the finite element method and linear algebra methods. At the first stage of the research, a patent and bibliographic search was conducted for existing designs of hip joint endoprosthesis acetabular components and methods of their fixation in the “pelvic bone – endoprosthesis” system. An analysis of modern world trends in hip joint endoprosthesis was performed. Promising designs of hip joint endoprosthesis acetabular components were determined. A finite element model has been developed to study the stress-strain state of elements of a healthy hip joint under operational loads. The stress-strain state calculations of elements of a healthy hip joint at expluatation have been carried out. The results of the work obtained at this stage will be used in the future in the development of finite element models for studying the stress-strain state of elements of a hip joint with acetabulum defects and an endoprosthesis under operational loads. Applied scientific research work on the topic III-125-24 is the development of joint research on biomechanical systems carried out within the framework of agreements on scientific and technical cooperation № 321-7 dated 01.02.2014 and № 362-7 dated 10.12.2021 with the Dnipro State Medical University.
Product Description
popup.authors
Horobets Dmytro V.
Mokrii Tetiana F.
Sobolevska Maryna B.
popup.nrat_date
2025-01-13