Registration Number
0303U003359,
0103U001854
, R & D reports
Title
Modernizing of vibration monitoring system ГПА ГТН-25
popup.stage_title
Модернізація системи віброконтролю ГПА ГТН-25
Head
Bozhko A.Ye.,
Registration Date
14-04-2003
Organization
A. Podgorny's Institute of Mechanical Engeneering Problems of the National Academy of Science of Ukraine
popup.description2
Within the framework of modernizing, calibration of amplifiers of signals from vibration transducers has been carried out on the vibration test bench ВЭДС-10А. With the aim of speeding up the response of the system to changes in the vibration level of functional units, the time constant of averaging circuits has been reduced. In the logical circuits that control forming of emergency signals, the locking of comparators after reducing the vibration level has been eliminated. Also, the delay time of the emergency signal, which is fed to the plant central control board, has been reduced by a factor of 2. Adjustment of the vibration monitoring channels and their checking on the vibration test bench has been carried out, and the results obtained have been treated. The vibration monitoring system has been commissioned at ГПА ГТН-25 № 3 at the Romny Compressor Station.
Product Description
popup.authors
popup.nrat_date
2020-04-03