Registration Number
0226U001533,
(0124U000667)
, R & D reports
Title
Development of a test kit for the detection of the genetic material of the causative agent of anthrax based on quantitative PCR and recombinant technologies with the aim of improving the disease control system in conditions of armed aggression by the Russian Federation and post-war recovery of Ukraine
popup.stage_title
Розроблення тест-системи для виявлення генетичного матеріалу збудника сибірки на основі кількісної ПЛР та рекомбінантних технологій з метою удосконалення системи контролю захворювання в умовах збройної агресії рф та повоєнного відновлення України
Head
Biloivan Oleksandr V., Кандидат ветеринарних наук
Registration Date
27-01-2026
Organization
National Scientific Center Institute of Experimental and Clinical Medicine
popup.description1
The goal of the project is to create a test kit for detecting the DNA of the anthrax pathogen in biological material and environmental samples using the PCR method. The test kit is planned to be based on recombinant positive control samples of specific DNA fragments of the anthrax pathogen, namely the chromosomal marker dhp61, the pagA gene fragment of the pXO1 plasmid, and the capC gene fragment of the pXO2 plasmid of Bacillus anthracis.
The amplification parameters will be optimized, as well as the concentrations of reaction mixture components. Coefficients of variation within one and several independent experiments will be determined. Analytical, diagnostic sensitivity, and specificity of the method will be established.
popup.description2
The study involved the development of key components of the PCR test kit “Anthrax-DNA-test” for detecting the genetic material of Bacillus anthracis. A recombinant positive control sample for detecting the chromosomal marker dhp61 was created using TA cloning with E. coli DH5α cells and the pTZ57R/T vector. The identity and correctness of the insert were confirmed by gel electrophoresis, sequencing, and real-time PCR.
An internal control sample (qPCR IC) was also obtained by cloning a fragment of the GFP gene, which helps prevent false-negative results during amplification. Both controls, along with previously produced recombinant samples for detecting the plasmid markers pagA and capC of the anthrax pathogen, were incorporated into the experimental PCR test kit together with primer and probe systems for detecting the specified DNA fragments.
A full set of validation tests was conducted, including determination of analytical sensitivity, specificity, and reproducibility of the method. Temperature profiles and concentrations of reaction mixture components were optimized, and working parameters of MgCl₂, primers, the probe, and Taq polymerase were established. Coefficients of variation (CV) within a series and between experiments ranged from 0–2.9%, which meets international standards and demonstrates the high accuracy of the test kit.
The linearity of qPCR was confirmed by correlation coefficients of R² = 0.9992–0.9999, indicating a direct dependence of the signal on DNA concentration. Specificity was evaluated using strains of the genus Bacillus and other infectious agents, with no cross-reactions detected.
A preliminary registration dossier for the test system has been prepared. Based on its sensitivity, specificity, and reproducibility indicators, the “Anthrax-DNA-test” is comparable to foreign analogues and meets WHO requirements. After registration, it is planned to be used for rapid anthrax diagnostics in Ukraine.
Product Description
popup.authors
Bolotin Vitalii I.
Didyk Tetiana B.
popup.nrat_date
2026-01-27