1 documents found
Information × Registration Number 0221U105016, 0121U110185 , R & D reports Title Calibration of the flowmeter "SMH" by the comparison method of the obtained values with the electromagnetic flowmeter values of the hydrodynamic stand of IPMash NAS of Ukraine popup.stage_title Head Rusanov Andrii V., Доктор технічних наук Registration Date 09-05-2021 Organization A. Podgorny Institute of Mechanical Engineering Problems of the National Academy of Sciences of Ukraine popup.description2 The object of research - flowmeters "CMX", produced by "ZAVOD MANOMETR". Purpose - to hold potassium edge flow "CMX" on hydrodynamic stand IPMash NAS in two positions flowmeter installation. Calibration was carried out on a liquid flow rate mode from 33 to 510 l/s. The values obtained were compared with the values of the electromagnetic flowmeter IPMash. Calibration of the flowmeter "SMH" produced by "ZAVOD Manometer" was carried out. The flowmeter spilled with the measuring tube set down at an angle of 45º to the horizon, the sensors were located below the edge of the measuring tube. Calibration of the flow meter was performed at flow rates: 115 l / s, 180 l / s, 250 l / s, 330 l / s, 355 l / s, 372 l / s, 430 l / s. High-frequency "noise" characteristics of pressure sensors with simulation of impulse line blockage are obtained.   Product Description popup.authors popup.nrat_date 2021-05-09 Close
R & D report
Head: Rusanov Andrii V.. Calibration of the flowmeter "SMH" by the comparison method of the obtained values with the electromagnetic flowmeter values of the hydrodynamic stand of IPMash NAS of Ukraine. (popup.stage: ). A. Podgorny Institute of Mechanical Engineering Problems of the National Academy of Sciences of Ukraine. № 0221U105016
1 documents found

Updated: 2026-03-17