1 documents found
Information × Registration Number 0299U000547, 0199U000068 , R & D reports Title Development of the method of calibration metrologies investigation and delivery of the standard voltage devider. popup.stage_title Head Surdu M.M., Registration Date 15-04-1999 Organization "SPETSAUTOMATIKA" State Scientiffic & Production Enterprise popup.description2 The standard devider metrologies parameter has been investigated. These investigations shown that devider has following parameter: main transfer function error -less than 0,0002%, additional error in all dynamic range - less than 0,0001%, additional error, caused by the power dissipation in standard resistors - less than 0,00005%/ Additional error, caused by environment temperature changing is less than 0,00001 1/oC Our investigations shown that devider technical data permits to include this one into primary state standard. It can be used to extend dynamic range of voltage measurement. Product Description popup.authors popup.nrat_date 2020-04-03 Close
R & D report
Head: Surdu M.M.. Development of the method of calibration metrologies investigation and delivery of the standard voltage devider.. (popup.stage: ). "SPETSAUTOMATIKA" State Scientiffic & Production Enterprise. № 0299U000547