Information × Registration Number 0302U001275, 0102U000569 , R & D reports Title To inspect the condition and to develop the recommendations for repair fix skip of trunk № 3 "Shaft by О.I.Gaevoy" popup.stage_title Дослідити стан і розробити рекомендації по ремонту кріплення скіпового ствола N3 "Шахти ім.О.І.Гаєвого" Head Budnik A.V., Registration Date 16-05-2002 Organization Research Institute of Organization and Mechanization of Mine Construction popup.description2 Skip a trunk № 3 sh.est. А.I.Gaevoy. Inspection of a trunk and development of the constructive - technological decisions on amplification and repair skip. Analytical researches, constructive - technological accounts, analysis of the engineering specifications. Five variants skip for repair broken parcel of a trunk are developed on the basis of modular steel and ferro-concrete elements and monolithic ferro-concrete, which are erected in exchange relevant skip or her strengthen. Maintenance of trouble-free operation of a trunk in complex mining and mine technical conditions. Fastening of vertical trunks. Repair and operation.5635 Product Description popup.authors popup.nrat_date 2020-04-02 Close
R & D report
Head: Budnik A.V.. To inspect the condition and to develop the recommendations for repair fix skip of trunk № 3 "Shaft by О.I.Gaevoy". (popup.stage: Дослідити стан і розробити рекомендації по ремонту кріплення скіпового ствола N3 "Шахти ім.О.І.Гаєвого"). Research Institute of Organization and Mechanization of Mine Construction. № 0302U001275